10+ years in HVAC Foshan, Guangdong, China CE · ISO 9001 · ISO 14001 · ISO 45001 · CRAA

Technical specifications

Select a category to compare models. Every table carries the model codes you need for an accurate inquiry — click “Inquire this series” to request pricing with the correct model reference. Data measured under nominal conditions as stated in each table.

Ducted concealed fan coil units hide above the ceiling and deliver air through short ducts — the standard choice for hotel guest rooms, offices and apartments where quiet matters and the unit itself should stay out of sight. Choose AC-motor models for budget projects or EC-motor models when running cost and low noise at part load are priorities.

High Capacity Hydronic Concealed Fan Coil Units — 2-Pipe AC Motor

FP-34 – FP-238 · 2-pipe AC motor
High capacity hydronic concealed fan coil unit with WIFI thermostat control
2-pipe AC motor FCU · cooling at water in 7 °C, heating at water in 60 °C
ItemUnitFP-34FP-51FP-68FP-85FP-102FP-136FP-170FP-204FP-238
Cooling capacitykW1.92.83.754.65.57.39.21112.8
Heating capacitykW3.45.186.677.59.3512.414.717.620.5
Air flowm³/h35753571489210711428178520902390
Motor powerW252025254040+2540+4040+4050+50
Water flowm³/h0.320.4780.640.7970.9561.2751.591.92.23
Power inputW3650607493130147183221
NoisedB(A)373941434547485052

Inquire this series — AC motor

Concealed FCU with EC Motor — Low Energy, Low Noise

FCU-02EC – FCU-14EC · motor power 60 W
FCU with EC motor · cooling at water in 7 °C, heating at water in 60 °C
ItemUnitFCU-02ECFCU-03ECFCU-04ECFCU-05ECFCU-06ECFCU-08ECFCU-10ECFCU-12ECFCU-14EC
Cooling capacitykW1.83.263.974.65.757.459.1910.812.7
Heating capacitykW3.495.276.778.6511.171315.9717.721.2
Power input (12 Pa)W1416.722.432.952.16072.892.7125.2
Power input (30 Pa)W19.824.332.543.56778.592.2116156
Power input (50 Pa)W26.332.442.555.782.298115.9155.5186
Noise (12 Pa)dB(A)18-3218-3020.3423-3829-4328-4232-4333-4437-47
Noise (30 Pa)dB(A)20-3820-3722-4124-4330-4731-4634-4734-4838-49
Noise (50 Pa)dB(A)23-4322-4225-4526-4733-5034-4936-5137-5139-53
Air flowm³/h36054572490010901440175021402490
Motor powerW60
Weightkg10.112.11314.215.520.123.525.527.3

Inquire this series — EC motor

Exposed units mount on the wall, floor or ceiling with no ducting at all — fastest to install and easiest to service. The horizontal (ceiling suspended) and vertical (floor standing) versions share the YG model range, so performance data stays comparable across installation styles.

Horizontal Exposed FCU — Ceiling Mounted, YG Series

YG-10 / YG-20 / YG-30 · performance under different fan speeds (1200–2000 RPM)
Horizontal exposed ceiling mounted fan coil units, YG series
YG series — data sheet under different fan speeds · cooling at 7 °C chilled water, heating at 45 °C / 60 °C hot water
ModelItem12001400160018002000 RPM
YG-10Air flow m³/h265300340370400
Power input W1419263235
Noise dB(A)3438424648
Cooling cap. (7 °C) kW0.91.11.251.351.4
Heating cap. (45 °C) kW0.991.21.381.41.45
Heating cap. (60 °C) kW1.561.872.122.32.38
Water flow m³/h0.20.230.260.290.32
Water pressure drop kPa1212141516
YG-20Air flow m³/h430500580660740
Power input W1623324562
Noise dB(A)3742454849
Cooling cap. (7 °C) kW1.681.922.152.352.59
Heating cap. (45 °C) kW1.832.072.332.572.73
Heating cap. (60 °C) kW33.353.744.154.5
Water flow m³/h0.30.330.360.390.42
Water pressure drop kPa1010121415
YG-30Air flow m³/h6307508609801060
Power input W2130446380
Noise dB(A)3944484952
Cooling cap. (7 °C) kW3.363.74.134.44.73
Heating cap. (45 °C) kW3.453.924.374.795.05
Heating cap. (60 °C) kW5.656.387.127.778.24
Water flow m³/h0.610.650.750.80.85
Water pressure drop kPa4145546370

Inquire this series — YG

Vertical Exposed FCU — Floor Standing, YG Series

YG-10 / YG-20 / YG-30 · floor standing
Vertical exposed floor standing fan coil unit, YG series
YG vertical series · data at 1200 RPM · cooling at 7 °C, heating at 45 °C
ItemUnitYG-10YG-20YG-30
Air flowm³/h265420630
Power inputW141621
Noise (1200 RPM)dB(A)343739
Cooling capacity (7 °C)kW0.91.683.36
Heating capacity (45 °C)kW0.991.833.45
Water flowm³/h0.20.30.61
Net weightkg15.317.923.3

Inquire this series — YG vertical

Cassette units mount flush in suspended ceilings and throw air in four directions — the go-to solution for offices, hotels, schools, shops and open-plan commercial spaces. Water-based chilled/hot water coils mean no refrigerant handling indoors, and the built-in condensate lift pump keeps installation simple.

4-Way Cassette Hydraulic FCU for Commercial Spaces

FP-34 – FP-238 · 360° all-direction airflow · built-in condensate lift pump · remote control · 220-240 V/1 ph/50 Hz
4-way cassette hydraulic fan coil unit, ceiling mounted
4-way cassette hydraulic FCU · data at high fan speed · cooling at water in 7 °C, heating at water in 60 °C
ItemFP-34FP-51FP-68FP-85FP-102FP-136FP-170FP-204FP-238
Cooling capacity (high) kW1.2151.9352.523.1053.7354.6356.37.298.01
Heating capacity (high) kW1.532.2952.883.694.3655.317.388.3259.045
Air flow (high) m³/h34051068085010201360170020402380
Power input W3450587292126128152198
Noise dB(A)373941434546474952
Weight kg21222330.53131.538.539.540.5
Power supply220 V~240 V / 1 ph / 50 Hz

Key features

  • Precise temperature control with included remote controller; 360° all-direction airflow for even distribution.
  • DN20 inlet and outlet ports make installation faster and easier.
  • Three-dimensional spiral wind wheel — powerful airflow with low-noise operation.
  • Built-in condensate lift pump drains water automatically, preventing overflow in continuous use.
  • Low-noise three-speed capacitor motor with imported precision ultra-low-noise rolling bearings.
Inquire — 4-way cassette

Cassette FCU for Hospitals & Healthcare

Water-based system — no refrigerants like Freon · quiet operation for patient rooms & operating areas
Cassette fan coil unit designed for hospital environments
Cassette FCU for healthcare · data at high fan speed · cooling at water in 7 °C, heating at water in 60 °C
ItemFP-34FP-51FP-68FP-85FP-102FP-136FP-170FP-204FP-238
Cooling capacity (high) kW1.2151.9352.523.1053.7354.6356.37.298.01
Heating capacity (high) kW1.532.2952.883.694.3655.317.388.3259.045
Air flow (high) m³/h34051068085010201360170020402380
Power input W3450587292126128152198
Noise dB(A)373941434546474952
Weight kg21222330.53131.538.539.540.5
Power supply220 V~240 V / 1 ph / 50 Hz

Why water-based cassettes for hospitals

  • Energy-efficient: no refrigerants like Freon — better energy efficiency and lower operational costs.
  • Smart temperature control: multiple temperature settings for different hospital zones.
  • Low noise: quiet running for patient rooms and operating theatres.
  • Flexible installation: space-saving cassette design suits complex hospital layouts.
  • Proven in projects: delivered for inpatient wards, operating rooms and public areas of large comprehensive hospitals, with load estimation (ASHRAE methods) and selection support included.
Inquire — healthcare cassette

Monoblock air-to-water heat pumps cover heating, cooling and domestic hot water from one outdoor unit. R290 models reach the highest efficiency (ERP A+++ at 35 °C outlet water) and up to 75 °C maximum outlet temperature; R32 models extend to 26 kW for larger homes and light commercial use.

R290 Monoblock Heat Pumps — BLN Series

BLN-006TC1 – BLN-018TC3 · R290 refrigerant · ERP A+++ · max outlet water temp. 75 °C
R290 monoblock heat pumps, BLN series
BLN series · nominal heating (max) at A7/6 °C, W30/35 °C
ItemUnitBLN-006TC1BLN-008TC1BLN-008TC3BLN-012TC1BLN-012TC3BLN-018TC1BLN-018TC3
Power supply—220~240/1/50220~240/1/50380~415/3/50380~415/3/50380~415/3/50220~240/1/50380~415/3/50
Heating capacity (A7/W35)kW2.92~9.104.10~12.104.10~12.104.30~15.204.30~15.207.24~21.907.24~21.90
Power input (A7/W35)kW0.61~2.110.61~2.110.79~2.850.87~3.730.87~3.731.50~5.881.50~5.88
COP (A7/W35)W/W4.31~5.664.31~5.664.24~5.574.07~5.574.07~5.573.82~5.593.82~5.59
Heating capacity (A7/W55)kW2.99~8.162.99~8.164.05~12.154.25~14.554.25~14.556.36~19.456.36~19.45
COP (A7/W55)W/W2.79~3.462.79~3.462.99~3.452.83~3.452.83~3.452.84~3.572.84~3.57
ERP level (outlet 35 °C)—A+++
Rated input powerkW3.53.55.45.855.857.510.5
Refrigerant type / charge / GWP—R290/0.55/3R290/1.05/3 (R290/1.4/3 for 018)
Rated water flowm³/h11.41.42.062.063.13.1
Fan motor / Compressor—DC inverter / DC inverter
Circulating pump—Inverter type / built-in
IP class—IPX4
Sound pressure at 1 mdB(A)46434353545656
Max. outlet water temp.°C75
Water connectionsinchG1G1G1G1G1G1¼G1¼
Water pressure dropkPa20202020205050
Operating range (heating / cooling)°C−25~45 / 16~45 (ambient)
Dimensions L×D×Hmm1187×418×8051287×448×9041287×448×9041287×448×9041287×448×9041187×488×14561187×488×1456
Net weightkg110134134134134195195

Inquire this series — BLN

R32 Monoblock Heat Pumps — MMHP Series

MMHP-008B1 – MMHP-026B2 · R32 refrigerant · max outlet water temp. 60 °C · operating ambient −25~45 °C
R32 monoblock heat pumps, MMHP series
MMHP series · Heating¹: A7/6 °C, W30/35 °C · Heating²: A7/6 °C, W47/55 °C · Cooling: A35/24 °C, W12/7 °C
ItemUnitMMHP-008B1MMHP-012B1MMHP-016B1MMHP-020B1MMHP-012B2MMHP-016B2MMHP-020B2MMHP-026B2
Power supply—220-240V~/50Hz220-240V~/50Hz220-240V~/50Hz220-240V~/50Hz380-415V~/3N/50Hz380-415V~/3N/50Hz380-415V~/3N/50Hz380-415V~/3N/50Hz
Heating¹ capacitykW2.50-8.304.20-12.205.30-16.506.20-20.54.20-12.205.30-16.506.20-20.56.50-26.10
Heating¹ input powerkW0.57-1.920.86-2.881.15-4.151.36-5.280.86-2.881.15-4.151.36-5.281.78-6.45
Heating² capacitykW2.30-7.623.85-11.204.90-15.106.30-19.903.85-11.204.90-15.106.30-19.906.90-26.10
Heating² input powerkW0.75-2.611.13-3.751.65-5.251.65-6.821.13-3.751.65-5.251.65-6.821.95-8.55
Cooling capacitykW1.80-7.102.60-10.304.50-13.505.50-17.502.60-10.304.50-13.505.50-17.505.20-21.30
Cooling input powerkW0.61-2.430.91-3.651.45-4.851.65-6.250.91-3.651.45-4.851.65-6.251.95-8.20
SCOP (water 35 °C)—4.924.554.584.674.554.584.674.85
SCOP (water 55 °C)—3.373.413.393.453.413.393.453.42
EER (water 7 °C)—3.163.123.153.153.123.153.153.16
Rated input powerkW2.713.836.27.53.836.27.510
Refrigerant type / charge / GWP—R32/1.25/675R32/1.80/675R32/2.8/675R32/2.8/675R32/1.80/675R32/2.8/675R32/2.8/675R32/3.5/675
IP class—IPX4
Max. outlet water temp.°C60
Operating ambient temperature°C−25 ~ 45
Water connectionsinchG1"G1"G1-1/4G1-1/2G1"G1-1/4G1-1/2G1-1/2
Rated water flowm³/h1.11.752.523.21.752.523.24.12
Water pressure dropkPa2527303227303235
Noise leveldB(A)5052555652555658
Dimensions L×W×Hmm1000×445×8501000×445×8501110×480×8501110×445×14501000×445×8501110×480×8501110×445×14501110×445×1450
Net weightkg102107124151107124151160